層流手術(shù)室是采用空氣潔凈技術(shù)對微生物污染采取程度不同的控制,達(dá)到控制空間環(huán)境中空氣潔凈度適于各類手術(shù)之要求;并提供適宜的溫、濕度,創(chuàng)造一個潔凈舒適的手術(shù)空間環(huán)境。由于手術(shù)室要嚴(yán)格控制低細(xì)菌數(shù)及低麻醉氣體濃度,所以層流超凈裝置的穩(wěn)定性是層流凈化手術(shù)室的重要驗(yàn)收指標(biāo)。由于歐美手術(shù)室潔凈標(biāo)準(zhǔn)與中國環(huán)境存在細(xì)微差別,常規(guī)的標(biāo)準(zhǔn)和國內(nèi)區(qū)域行業(yè)標(biāo)準(zhǔn)都普遍難于確保手術(shù)室凈化的長期穩(wěn)定(一般只能3-10年重建、低檔工程1年即需要翻新),所以在工程質(zhì)量方面出現(xiàn)了明顯的檔次劃分。一些知名凈化工程公司,在通行標(biāo)準(zhǔn)之外,基本都設(shè)有自身執(zhí)行的高于化通行標(biāo)準(zhǔn)的凈化指標(biāo)。
The laminar flow operating room adopts the air cleaning technology to control the microbial pollution in different degrees, so as to meet the requirements of controlling the air cleanliness in the space environment, which is suitable for all kinds of
operations, and to provide appropriate temperature and humidity, so as to create a clean and comfortable operating space environment. Because the operating room should strictly control the low number of bacteria and low concentration of anesthetic
gas, the stability of laminar flow ultra clean device is an important acceptance index of laminar flow purification operating room. Due to the subtle differences between European and American operating room cleaning standards and China's environment,
conventional international standards and domestic regional industry standards are generally difficult to ensure the long-term stability of operating room cleaning (generally only 3-10 years of reconstruction, low-grade projects need to be renovated
in one year), so there is an obvious level division in engineering quality. Some well-known purification engineering companies, in addition to the general standards, basically have their own purification indicators that are higher than the international
general standards.
1 潔凈手術(shù)部應(yīng)設(shè)在耐火等級不低于二級的建筑物內(nèi)。
1. The clean operation department shall be located in a building with a fire resistance rating of no less than grade II.
2 潔凈手術(shù)部宜劃分為單獨(dú)的防火分區(qū)。當(dāng)與其他部位處于同一防火分區(qū)時,應(yīng)采取有效的防火防煙分隔措施,并應(yīng)采用耐火極限不低于2.00H的隔墻與其他部位隔開;與非潔凈手術(shù)部區(qū)域相連通的門應(yīng)采用耐火極限不低于乙級的防火門(直接通向敞開式外走廊或直接對外的門除外),或其他相應(yīng)的防火技術(shù)措施。
2. The clean operation department should be divided into separate fire zones. When it is in the same fire compartment with other parts, effective fire and smoke prevention and separation measures shall be taken, and partition wall with fire resistance
not less than 2.00h shall be used to separate it from other parts; fire doors with fire resistance not less than class B (except for doors directly leading to open external corridor or directly external) or other corresponding fire prevention
technical measures shall be used for doors connecting with non clean operation Department Application.
3 潔凈手術(shù)部的技術(shù)夾層與手術(shù)室、輔助用房等相連通的部位應(yīng)采取防火防煙措施,其分隔體的耐火極限不應(yīng)低于1.00H。
3. Fire and smoke prevention measures shall be taken for the technical mezzanine of clean operating department, operating room, auxiliary room and other connected parts, and the fire resistance limit of its separator shall not be less than 1.00h.
4 當(dāng)需要設(shè)置室內(nèi)消火栓時,可不在手術(shù)室內(nèi)設(shè)置消火栓,但設(shè)置在手術(shù)室外的消火栓應(yīng)能保證2只水槍的充實(shí)水柱同時到達(dá)手術(shù)室內(nèi)任何部位;當(dāng)潔凈手術(shù)部不需設(shè)室內(nèi)消火栓時,應(yīng)設(shè)置消防軟管卷盤等滅火設(shè)施。當(dāng)需要設(shè)置自動噴水滅火系...
4 when indoor fire hydrants are required, fire hydrants may not be set in the operating room, but the fire hydrants set in the operating room shall ensure that the full water column of two water guns can reach any part of the operating room at the same
time; when indoor fire hydrants are not required in the clean operating Department, fire hose reels and other fire-fighting facilities shall be set. When automatic sprinkler system is needed
昆山昌瑞空調(diào)凈化技術(shù)有限公司,專注從事